FIBC Types
FIBC Classification Type A, B, C, D
Bulk product in FIBC | Surrounding | ||
---|---|---|---|
MIE of dust | Non-flammable atmosphere | Dust zones 21-22 (1000 mJ ≥ MIE > 3 mJ) | Gas zones 1-2 (Groups IIA/IIB) or Dust zones 21-22 (MIE ≤ 3mJ) |
MIE > 1000 mJ | A, B, C, D | B, C, D | C, D |
1000 mJ ≥ MIE > 3 mJ | B, C, D | B, C, D | C, D |
MIE ≤ 3 mJ | C, D | C, D | C, D |
Plain Bag - No Static Protection
Safe use:
- To transport non-flammable products
- No flammable solvents or gases present around the bag
Do not use:
- To transport flammable products
- When flammable solvents or gases are present around the bag
Read More...
Plain Bag - Low Breakdown Voltage
Prevents Propagating Brush Discharges
Safe use:
- To transport dry, flammable powders
- No flammable solvents or gases present around the bag
Do not use:
- When flammable solvents or gases are present around the bag
Interconnected Conductive Threads Dissipates Charge to Ground RG < 108 ohm
Safe use:
- To transport flammable powders
- When flammable solvents or gases are present around the bag
Do not use:
- When ground connection is not present or has become damaged
Does Not Require Grounding/Earthing
Safe use:
- To transport flammable powders
- When flammable solvents or gases are present around the bag
Do Not Use:
- When the surface is heavily contaminated or coated with conductive material such as water or grease
Note: There is no official standard classification, "Groundable Type D", D+, Dplus or CD. IEC 61340-4-4 Ed. 2.0 & Ed. 3.0 do not permit FIBC to be